Mixed-vendor installations require an exact compatibility identity at each host. This 0.5m (2ft) DAC cable is prepared for equipment expecting Generic OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT, providing 800G connectivity through OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top). Equivalent-length brand links and separate length pages make it easier to document both ends of the connection correctly.
OEM Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FTHT Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT
| HT Part Number | OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 0.5m (2ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 58mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 0.1W (800G End)0.1W (400G Per End) |
| Modulation Format | 8x 100G-PAM4 to Dual 4x 100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/400G Ethernet |
| Protocols | OSFP MSA Rev5.0, IEEE 802.3ck, CMIS 4.0 |
The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
This assembly uses 30AWG conductors, PET jacket, minimum bend radius 58mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA Rev5.0, IEEE 802.3ck, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 58mm; the stated power consumption is 0.1W (800G End)0.1W (400G Per End); the jacket material is PET.
The rated power consumption is 0.1W (800G End)0.1W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT associated with 0.5m (2ft) throughout the order and receiving record.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.