The MCP7Y00-N00A compatible assembly is a 800G DAC cable for NVIDIA/Mellanox hosts, built in 0.5m (2ft) with 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top). It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.
OEM Part Number: MCP7Y00-N00AHT Part Number: MCP7Y00-N00A
| HT Part Number | MCP7Y00-N00A |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCP7Y00-N00A |
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Minimum Bend Radius | 58mm |
| Max. Power Consumption | 0.1W @800G, 0.1W @400G |
| Cable Length | 0.5m (2ft) |
| Wire AWG | 30AWG |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Jacket Material | PET |
| Modulation Format | 8x 100G-PAM4 to Dual 4x 100G-PAM4 |
| Application | 800G InfiniBand NDR |
| Protocols | OSFP MSA Rev5.0, IEEE 802.3ck, CMIS 4.0 |
The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing MCP7Y00-N00A; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
MCP7Y00-N00A is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is MCP7Y00-N001 at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 58mm; the stated power consumption is 0.1W @800G, 0.1W @400G; the jacket material is PET.
The rated power consumption is 0.1W @800G, 0.1W @400G. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PET jacket, minimum bend radius 58mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G InfiniBand NDR. Listed interface and protocol references include OSFP MSA Rev5.0, IEEE 802.3ck, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.
The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7Y00-N00A.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.