The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT compatible assembly is a 800G DAC cable for Generic hosts, built in 1m (3ft) with OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top). It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.
OEM Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FTHT Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT
| HT Part Number | OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 1m (3ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 58mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 0.1W (800G End)0.1W (400G Per End) |
| Modulation Format | 8x 100G-PAM4 to Dual 4x 100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/400G Ethernet |
| Protocols | OSFP MSA Rev5.0, IEEE 802.3ck, CMIS 4.0 |
The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
At 1m (3ft), OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT occupies the middle of this family between OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT at 0.5m (2ft) and OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 58mm; the stated power consumption is 0.1W (800G End)0.1W (400G Per End); the jacket material is PET.
The rated power consumption is 0.1W (800G End)0.1W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PET jacket, minimum bend radius 58mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA Rev5.0, IEEE 802.3ck, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT associated with 1m (3ft) throughout the order and receiving record.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.