LC to SC Duplex Armored Fiber Patch Cable, OS2, LSZH

LC to SC Duplex Armored Fiber Patch Cable, OS2, LSZH

Malaysian upgrade projects can use this configuration where its interface and fiber map align with both the installed cabling and the new hardware. This duplex armored patch cable joins an LC UPC pair on one end to an SC UPC pair on the other, on OS2 9/125µm single-mode fiber inside a helical stainless steel tube with a low smoke zero halogen jacket. It is the single-cord answer when modern LC-equipped hardware has to land on a SC-terminated plant inside a building zone where LSZH cabling is specified. Malaysian upgrade teams can use this detail to compare the new assembly with the installed cabling records.

Product Highlights

  • LC UPC to SC UPC hybrid duplex, OS2 9/125µm single mode
  • LSZH jacket: low smoke, zero halogen in a fire
  • Helical stainless steel armor against crush, impact and rodents
  • G.657.A1 bend-insensitive fiber, 10/5D bend radius
  • Insertion loss ≤0.3dB, return loss ≥50dB
  • Stock lengths 1m to 30m; custom lengths and jackets on request

Specifications

Connector TypeLC to SC
Polish TypeUPC to UPC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountDuplex
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingLSZH (Low Smoke Zero Halogen)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

Mixed LC and SC interfaces in one tested cord

A hybrid duplex cord removes this mating adapter pair that would otherwise sit between the connected hardware and the frame: LC on the transceiver side, SC on the mounted panel side, the two terminated and tested as one assembly. Each adapter eliminated is a mated pair and its loss removed from the channel, and one less part to stock, clean and eventually troubleshoot.

Where LSZH is specified

Tunnels, stations, airports, hospitals, ships and high-occupancy office towers routinely forbid halogenated cable jackets as of the smoke and corrosive gas they emit in a fire. This cord meets those specifications while keeping the armored construction, meaning that the safety case and the mechanical case are the two satisfied by the same part number.

Steel armor under a low-smoke jacket

Public-area pathways see more abuse than hardware rooms: cleaning hardware, luggage, maintenance work and constant foot traffic. The helical stainless tube inside the LSZH jacket absorbs that abuse without conduit, and at 3.0mm the cord still routes through standard managers and surface raceway.

Upgrading mixed-interface plants safely

Buildings that grew over decades commonly present SC on the riser side and LC on the new hardware side. A hybrid armored LSZH cord makes that transition link by link, with no adapter inventory and no change to the fixed plant. As the plant gradually re-terminates toward LC, the same family supplies the LC-LC LSZH version, meaning that the jacket policy and the protection level stay constant through the migration.

Available lengths and custom orders

Normal length options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Customized cable lengths beyond this range are manufactured to order. Surveyed public-area routes should be ordered at the measured length so no surplus cable accumulates in the evacuation pathway or raceway. Specifying the exact route length avoids the two the slack storage problem of an overlong cord and the strain risk of one that is too short.

Testing and inspection practice

Every hybrid assembly is terminated with precision zirconia ferrules on the two interfaces and measured for insertion loss and return loss before packing; the 0.3dB and 50dB figures are verified per cord. Ferrule geometry is checked on the two polish ends, and the LSZH compound is batch-verified against the jacket specification.

Ordering and Customization Support

Refer to the LC-SC OS2 LSZH armored family when seeking a quotation, stating the route length and referencing the LSZH need. An LC to SC APC variant exists in the same jacket system, and other connector mixes are available through the project-specific armored program. For Malaysian upgrades, our team can compare the requested build with the existing environment before production begins.