Malaysian upgrade projects can use this configuration where its interface and fiber map align with both the installed cabling and the new hardware. This is the configured-to-order duplex armored platform: two fibers of OS2 9/125µm G.657.A1 glass inside a helical stainless steel tube, terminated with any combination of LC, SC, FC, ST or LSH connectors in UPC or APC polish, and jacketed in riser (OFCR), LSZH or plenum (OFNP) compound in blue, black or white. Instead of adapting a stock cord to the job, the cord is built for the job from the start. Malaysian upgrade teams can use this detail to compare the new assembly with the installed cabling records.
| Connector Type | LC / SC / FC / ST / LSH, any end-to-end combination |
|---|---|
| Polish Type | UPC or APC per end |
| Fiber Mode | OS2 9/125µm |
| Wavelength | 1310/1550nm |
| Fiber Count | Duplex |
| Polarity | A (Tx) to B (Rx) |
| Jacket Color | Blue / Black / White |
| Cable Outside Diameter (OD) | 3.0mm |
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Flame Rating | Riser (OFCR) / LSZH / Plenum (OFNP) |
| Construction Type | Single Armored, Stainless Steel Tube |
| Tensile Strength | 120/225N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | UPC ≥50dB, APC ≥60dB (LC/SC/FC/ST); LSH APC ≥65dB |
| Operating Temperature | OFNP: 0 to 70°C; OFCR/LSZH: -20 to 70°C |
| Storage Temperature | -40 to 70°C (-40 to 158°F) |
LC on the transceiver, ST on the legacy panel, FC on the test set, LSH on the carrier frame: real networks mix interfaces, and this platform terminates any of them on either end of the same armored duplex cord. Hybrid builds arrive as one tested assembly, meaning that this mating adapter pairs and their extra loss simply never enter the link.
The jacket follows the building zone, not the other way round. Riser (OFCR) suits vertical shafts and general pathways; LSZH is specified for occupied public spaces, tunnels and transport; plenum (OFNP) is appropriate where the route crosses air-handling space. The armor and the optical core stay the same across all three, meaning that one drawing might mix jackets by zone without changing the optical budget.
Send the mating connector mix, polish, jacket, color and length; the factory confirms the manufacturable specification, then terminates, armors and tests the cords to that drawing. Each cord in the batch is measured for insertion loss and return loss against the same limits as the stock range, meaning that a made-to-order build carries no quality penalty.
Every made-to-order build is confirmed against a written configuration before the product is built, and that configuration becomes the reference for repeat orders. Label text, leg marking and packing might all be added to the same drawing, meaning that the second batch arrives identical to the first. For projects rolled out in phases, this repeatability is usually worth more than any single specification line.
Beyond the standard blue, the duplex platform is jacketed in black or white on request. Black serves outdoor-adjacent and security-conscious routes where the completed cable ought to not draw the eye; white disappears into finished interiors, hotel corridors and office raceway. Some administrations also use jacket color to independent networks or security zones on the same frame. State the color with the configuration and it is built into the jacket, not sleeved on afterward.
Normal length options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft). Because each cord is built to order, any length in between or beyond this range can generally be produced; for long runs the factory confirms reel and packing information with the quotation.
Made-to-order cords are tested to the same limits as the stock range: 0.3dB insertion loss ceiling and polish-right return loss, verified per assembly before packing. Ferrule geometry is checked on each end face, and APC ends are angle-verified, meaning that a mixed-polish build performs exactly as its two polishes provide.
Send the appropriate configuration: connector types per end, polish per end, jacket rating, color and length. The factory confirms the manufacturable specification and lead time with the quotation; drawings or photos of the current plant are welcome and speed up confirmation. For Malaysian upgrades, our team can compare the requested build with the existing environment before production begins.