Malaysian upgrade projects can use this configuration where its interface and fiber map align with both the installed cabling and the new hardware. This OS2 breakout cable terminates a 16-fiber MMC APC female connector into two MTP-8 APC Elite female legs. It comes with a direct single-mode fan-out for parallel-optics links that divide sixteen fibers into two eight-fiber interfaces. Factory-built harness polarity and labeled branches remove the need for an independent cassette and its further mated connections.
| Part Number | 16FMMCMTPSMF |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MMC Female (Non-Pinned) |
| Connector B | US Conec MTP® Elite Female (Non-Pinned) |
| Polish Type | APC to APC |
| Glass Fiber | G.657.A1 |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Fiber Count | 16 Fibers |
| Polarity | Harness Polarity |
| Cable Outside Diameter (OD) | 2.5mm |
| Cable Jacket | Plenum (OFNP) |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Tensile Strength (Long Term) | 30N |
| Tensile Strength (Short Term) | 100N |
| Insertion Loss | ≤0.35dB |
| Return Loss | ≥60dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
The MMC side concentrates all sixteen fibers in one VSFF housing, whereas every MTP branch carries eight fibers. This arrangement is right only when the port and panel design expects the same two-way assignment. All three connectors are female and non-pinned, meaning that the mating interfaces must come with guide pins. Determine the appropriate APC polish on each leg before connecting the finished product.
The specified insertion loss is 0.35dB maximum and return loss is at least 60dB. An installed link budget must document the MMC connection, the chosen MTP branch connection and any adapters farther along the route. Keeping the two branch identities in the test report and rack records makes it easier to isolate a fault to one eight-fiber path.
Available lengths are 1m (3ft), 2m (7ft) and 3m (10ft), with customized cable lengths in feet or meters. Choose a length that lets the breakout assembly body rest in a supported area rather than hang from the MMC port. Route the two MTP legs with gentle bends and avoid loading one branch differently from the other when dressing the completed cable.
Request 16FMMCMTPSMF in the two-leg OS2 breakout configuration, stating complete length and unit count. If branch labels or unequal leg lengths are needed for a particular rack layout, document a fan-out drawing with the inquiry. For Malaysian upgrades, our team can compare the requested build with the existing environment before production begins.