SC APC to SC APC Fiber Drop Cable, OS2, Custom Length

SC APC to SC APC Fiber Drop Cable, OS2, Custom Length

Malaysian upgrade projects can use this configuration where its interface and fiber map align with both the installed cabling and the new hardware. This fiber drop cable closes the last span of the FTTH access network, running from the distribution point or splice closure to the subscriber premises. The two terminations are factory terminated with SC APC connectors, meaning that the link plugs directly into the optical network terminal and the distribution hardware without field splicing. The completed cable is the proven flat drop construction: one OS2 9/125µm single-mode fiber of G.657.A2 bend-insensitive glass in a 2.0x5.0mm LSZH jacket, manufactured to the exact length the route requires.

Product Highlights

  • SC APC to SC APC, factory terminated and tested
  • G.657.A2 bend-insensitive fiber, 7.5mm minimum bend radius
  • Flat 2.0x5.0mm LSZH drop cable construction
  • Insertion loss ≤0.3dB, return loss ≥60dB
  • Plug-and-play installation, no field splicing required
  • Manufactured to the ordered route length

Specifications

Connector ASC APC
Connector BSC APC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber Count1 Fiber
Fiber GradeG.657.A2
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)60/40mm (Dynamic/Static)
Trunk Outside Diameter (OD)2.0x5.0mm
Breakout Outside Diameter (OD)2.0x3.0mm
Breakout Length300±50mm
Cable JacketLow Smoke Zero Halogen (LSZH)
Tensile Load400N (Short Term)
Crush Resistance500N/100mm (Short Term)
Insertion Loss≤0.3dB
Return Loss≥60dB
Attenuation at 1310nm≤0.4dB/km
Attenuation at 1550nm≤0.3dB/km
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-10 to 50°C (14 to 122°F)

The last-mile link in FTTH networks

Between the distribution point and the subscriber, the drop cable is the most frequently handled and most often replaced part of the access network. It crosses walls, window frames, conduit entries and the final indoor route to the optical network terminal. A factory-completed drop cable turns that span into a plug-and-play link: the installer routes the completed cable, seats the two connectors, and the subscriber is live. No splicer, no curing time and no field polishing enter the plan, which is exactly what high-volume FTTH rollouts need.

Why APC polish matters in PON access

Access networks built on GPON and XGS-PON carry downstream video overlay and high-power optical budget on shared splitters, where reflections travel back toward each subscriber on the PON. The angled physical contact end-face of the SC APC connector keeps return loss at 60dB or better, steering reflections away from the upstream path. Mixing UPC cords into an APC-planned PON creates reflectance events that are hard to trace later, meaning that the drop segment ought to follow the APC discipline of the rest of the plant.

G.657.A2 glass for real subscriber premises

The indoor part of a drop route turns around door frames, baseboards and furniture edges, and it is often stapled or clipped by installers working quickly. G.657.A2 fiber tolerates a 7.5mm bend radius at the glass level, meaning that the tight corners of a real apartment do not add measurable loss. The flat 2.0x5.0mm construction with its parallel strength members keeps the completed cable lying flat against surfaces and protects the core from the crushing loads of staples and clips.

Custom length as the standard practice

Drop routes vary from a few meters in a townhouse to over a hundred meters on a rural lot, and a wrong guess in either direction costs time: too short means a replacement visit, too long means a coil of slack at the terminal. Ordering the drop cable to the measured route length removes the two failure modes. The 300mm breakout at the mating connector ends is part of the standard build, giving enough free fiber to dress into the closure or the terminal without strain.

Built to the measured route length

Each drop cable in this family is manufactured to the length stated with the order rather than picked from fixed stock sizes, as last-mile routes differ from a few meters to well over a hundred. The completed cable is manufactured to the length stated with the order; measure the route including the vertical drops and the entry path, and allow working slack at the two terminations for the closure and the terminal. Specifying the measured route length avoids the two the slack storage problem of an overlong cable and the strain risk of one that is too short.

Testing and inspection practice

Each drop cable is terminated with precision zirconia ferrule SC APC connectors and optically tested before packing: insertion loss is verified against the 0.3dB ceiling and return loss against the 60dB minimum on every assembly. End-face geometry is inspected for consistent physical contact, meaning that the delivered cable can generally be plugged in and put into service without on-site rework.

Ordering and Customization Support

Refer to the SC APC to SC APC drop cable family when seeking a quotation and state the route length and unit count per length. For sealed outdoor termination at the distribution end, the hardened-connector versions of this family mate directly with IP68 terminal ports; send the site need with the inquiry and the factory will determine the build before the product is built. For Malaysian upgrades, our team can compare the requested build with the existing environment before production begins.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my