Where a network combines several equipment vendors, select this assembly by the Generic QSFP-DD to 2x QSFP56-400G-ACC-5M16FT requirement rather than by its connector shape alone. This page covers the 5m (16ft) ACC version at 400G, including its QSFP-DD to 2x QSFP56 configuration, related brand identities and factory operating checks.
OEM Part Number: QSFP-DD to 2x QSFP56-400G-ACC-5M16FTHT Part Number: QSFP-DD to 2x QSFP56-400G-ACC-5M16FT
| HT Part Number | QSFP-DD to 2x QSFP56-400G-ACC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 2x QSFP56 |
| Max. Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Active |
| Cable Length | 5m (16ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 80mm |
| Max. Power Consumption | 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End) |
| Jacket Material | PVC |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFF-8636, SFF-8679 |
The rated power consumption is 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
The QSFP-DD to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The 5m (16ft) length gives QSFP-DD to 2x QSFP56-400G-ACC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
QSFP-DD to 2x QSFP56-400G-ACC-5M16FT is the longest of 4 verified length options in this family. Compared with QSFP-DD to 2x QSFP56-400G-ACC-3M10FT at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 80mm; the stated power consumption is 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End); the jacket material is PVC.
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 80mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8636, SFF-8679. Confirm that the host firmware and port configuration support the same operating mode.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep QSFP-DD to 2x QSFP56-400G-ACC-5M16FT associated with 5m (16ft) throughout the order and receiving record.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. QSFP-DD to 2x QSFP56-400G-ACC-5M16FT refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.