QSFP-DD to 2x QSFP56-400G-ACC-2M7FT 400G QSFP-DD 8 x 50G PAM4 to 2 x 200G QSFP56 4 x 50G PAM4 Active Copper Breakout Cable, 2m (7ft)

QSFP-DD to 2x QSFP56-400G-ACC-2M7FT 400G QSFP-DD 8 x 50G PAM4 to 2 x 200G QSFP56 4 x 50G PAM4 Active Copper Breakout Cable, 2m (7ft)

Where a network combines several equipment vendors, select this assembly by the Generic QSFP-DD to 2x QSFP56-400G-ACC-2M7FT requirement rather than by its connector shape alone. This page covers the 2m (7ft) ACC version at 400G, including its QSFP-DD to 2x QSFP56 configuration, related brand identities and factory operating checks.

OEM Part Number: QSFP-DD to 2x QSFP56-400G-ACC-2M7FTHT Part Number: QSFP-DD to 2x QSFP56-400G-ACC-2M7FT

Product Highlights

  • HT-manufactured ACC assembly in 2m (7ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 2x QSFP56
  • Fixed length and part number: 2m (7ft), QSFP-DD to 2x QSFP56-400G-ACC-2M7FT
  • Cable construction: Active
  • Conductor specification: 30AWG
  • Maximum power consumption: 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End)
  • Minimum bend radius: 70mm

Specifications

HT Part NumberQSFP-DD to 2x QSFP56-400G-ACC-2M7FT
ManufacturerHT
Form FactorQSFP-DD to 2x QSFP56
Max. Data Rate400Gbps
MediaCopper
Cable TypeActive
Cable Length2m (7ft)
Wire AWG30AWG
Minimum Bend Radius70mm
Max. Power Consumption1.45W(QSFP-DD End) 0.62W(QSFP56 Per End)
Jacket MaterialPVC
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8636, SFF-8679

Power and Thermal Planning

The rated power consumption is 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Position Within the Length Range

QSFP-DD to 2x QSFP56-400G-ACC-2M7FT occupies the middle of this family between QSFP-DD to 2x QSFP56-400G-ACC-1M3FT at 1m (3ft) and QSFP-DD to 2x QSFP56-400G-ACC-3M10FT at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 70mm; the stated power consumption is 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End); the jacket material is PVC.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 70mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8636, SFF-8679. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

QSFP-DD to 2x QSFP56-400G-ACC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Quantity and any labeling instructions should be attached specifically to QSFP-DD to 2x QSFP56-400G-ACC-2M7FT.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.