Where a network combines several equipment vendors, select this assembly by the Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT requirement rather than by its connector shape alone. This page covers the 0.5m (2ft) DAC version at 800G, including its OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) configuration, related brand identities and factory operating checks.
OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-0.5M2FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT
| HT Part Number | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive DAC |
| Cable Length | 0.5m (2ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 54mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 0.1W Per End |
| Modulation Format | 8x100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G Ethernet |
| Protocols | OSFP MSA, IEEE 802.3ck, CMIS v4.0 |
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
This assembly uses 30AWG conductors, PET jacket, minimum bend radius 54mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G Ethernet. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 54mm; the stated power consumption is 0.1W Per End; the jacket material is PET.
The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
No. OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.