Juniper Networks OSFP-800G-DAC-0.5M Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top Passive Copper Twinax Cable, 0.5m (2ft)

Juniper Networks OSFP-800G-DAC-0.5M Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top Passive Copper Twinax Cable, 0.5m (2ft)

Mixed-vendor installations require an exact compatibility identity at each host. This 0.5m (2ft) DAC cable is prepared for equipment expecting Juniper Networks OSFP-800G-DAC-0.5M, providing 800G connectivity through OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top). Equivalent-length brand links and separate length pages make it easier to document both ends of the connection correctly.

OEM Part Number: OSFP-800G-DAC-0.5MHT Part Number: OSFP-800G-DAC-0.5M

Product Highlights

  • Compatible alternative to Juniper Networks OSFP-800G-DAC-0.5M
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 0.5m (2ft), OSFP-800G-DAC-0.5M
  • Cable construction: Passive DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W Per End
  • Minimum bend radius: 54mm

Specifications

HT Part NumberOSFP-800G-DAC-0.5M
Juniper Networks CompatibleOSFP-800G-DAC-0.5M
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate800Gbps
MediaCopper
Cable TypePassive DAC
Cable Length0.5m (2ft)
Jacket MaterialPET
Minimum Bend Radius54mm
Wire AWG30AWG
Max. Power Consumption0.1W Per End
Modulation Format8x100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G Ethernet
ProtocolsOSFP MSA, IEEE 802.3ck, CMIS v4.0

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Power and Thermal Planning

The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 54mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G Ethernet. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing OSFP-800G-DAC-0.5M; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

OSFP-800G-DAC-0.5M is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP-800G-DAC-1M at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 54mm; the stated power consumption is 0.1W Per End; the jacket material is PET.

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Juniper Networks Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks OSFP-800G-DAC-0.5M.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. OSFP-800G-DAC-0.5M refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.