MMC-16 APC to 2 x MTP-8 UPC Breakout Cable, 16 Fibers, OM4

MMC-16 APC to 2 x MTP-8 UPC Breakout Cable, 16 Fibers, OM4

Malaysian upgrade projects can use this configuration where its interface and fiber map align with both the installed cabling and the new hardware. The 16FMMCMTPOM4 APC-to-UPC breakout divides sixteen OM4 fibers from one MMC APC female connector into two MTP-8 UPC female branches. It is built for multimode channels that require this exact polish combination. The direct fan-out replaces cassette-based conversion with one factory-tested assembly and two clearly and consistently identifiable eight-fiber paths.

Product Highlights

  • MMC Female to MTP® Female, 16 Fibers
  • OM4 50/125μm, bend-insensitive fiber
  • MMC insertion loss ≤0.35dB, return loss ≥40/27dB (MMC/MTP®)
  • Harness Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCMTPOM4
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to UPC
Glass FiberBend Insensitive Fiber
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Fiber Count16 Fibers
PolarityHarness Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥40/27dB (MMC/MTP®)
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140℉)
Storage Temperature-10 to 70°C (14 to 158℉)

A mixed-polish multimode fan-out

APC at the MMC-side interface and UPC at the two MTP ends must agree with the surrounding interfaces; this variant ought to not be substituted for the APC-to-APC breakout. The female, non-pinned connectors require pinned mates. Because the two MTP branches may serve different destination ports, label every individual branch and record its assignment before dressing the completed cable into a manager.

Reflection and insertion-loss values by connector

Maximum insertion loss is 0.35dB. Return loss is specified individually as at least 40dB for the MMC APC interface and 27dB for the MTP UPC interface. Those figures should be retained in acceptance documentation rather than replaced by a single universal value. OM4 fiber supports the 850/1300nm multimode channel, whereas reach remains determined by the chosen transceivers.

Installing the two-leg assembly

The standard complete lengths are 1m (3ft), 2m (7ft) and 3m (10ft); made-to-order meter and foot lengths are available. Position the breakout assembly so neither MTP leg is pulled sideways, and respect the 7.5mm optical-fiber bend radius. Clean and inspect the MMC and the two MTP ferrules before making the three connections.

Ordering and Factory Support

Provide 16FMMCMTPOM4 in the APC-to-UPC two-branch version, with length and unit count. For repeat installations, made-to-order branch IDs and a customer part-number label might keep these mixed-polish cables distinct from the APC-to-APC variants. For Malaysian upgrades, our team can compare the requested build with the existing environment before production begins.