SFP28 to SFP28-25G-DAC-4M13FT 25G SFP28 Passive Copper Twinax Cable, 4m (13ft)

SFP28 to SFP28-25G-DAC-4M13FT 25G SFP28 Passive Copper Twinax Cable, 4m (13ft)

The SFP28 to SFP28-25G-DAC-4M13FT compatible assembly is a 25G DAC cable for Generic hosts, built in 4m (13ft) with SFP28 to SFP28. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: SFP28 to SFP28-25G-DAC-4M13FTHT Part Number: SFP28 to SFP28-25G-DAC-4M13FT

Product Highlights

  • HT-manufactured DAC assembly in 4m (13ft)
  • 25G connectivity at 25Gbps
  • Interface configuration: SFP28 to SFP28
  • Fixed length and part number: 4m (13ft), SFP28 to SFP28-25G-DAC-4M13FT
  • Conductor specification: 26AWG
  • Minimum bend radius: 28mm

Specifications

HT Part NumberSFP28 to SFP28-25G-DAC-4M13FT
ManufacturerHT
Connector TypeSFP28 to SFP28
Max Data Rate25Gbps
Minimum Bend Radius28mm
Wire AWG26AWG
Cable Length4m (13.12ft)
Jacket MaterialPVC (OFNR)
Temperature0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000
Application25G Ethernet, Data Center, 5G Wireless

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28mm; the jacket material is PVC (OFNR).

Network and Protocol Considerations

The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 4m (13ft) length gives SFP28 to SFP28-25G-DAC-4M13FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.

Position Within the Length Range

SFP28 to SFP28-25G-DAC-4M13FT occupies the middle of this family between SFP28 to SFP28-25G-DAC-3M10FT at 3m (10ft) and SFP28 to SFP28-25G-DAC-5M16FT at 5m (16ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep SFP28 to SFP28-25G-DAC-4M13FT associated with 4m (13ft) throughout the order and receiving record.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my