
Where a network combines several equipment vendors, select this assembly by the Cisco SFP-H10GB-CU50CM requirement rather than by its connector shape alone. This page covers the 0.5m (2ft) DAC version at 10G, including its SFP+ to SFP+ configuration, related brand identities and factory operating checks.
OEM Part Number: SFP-H10GB-CU50CMHT Part Number: SFP-H10GB-CU50CM
| HT Part Number | SFP-H10GB-CU50CM |
|---|---|
| Cisco Compatible | SFP-H10GB-CU50CM |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Media | Copper |
| Power Supply | 3.3V |
| Minimum Bend Radius | 23mm |
| Wire AWG | 30AWG |
| Cable Length | 0.5m (1.64ft) |
| Jacket Material | PVC (OFNR) |
| Cable Type | Passive Twinax |
| Temperature | 0 to 70°C (32 to 158°F) |
| Power Consumption | ≤0.1W |
| Application | 10G Ethernet |
| Protocols | 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel |
The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing SFP-H10GB-CU50CM; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
SFP-H10GB-CU50CM is the shortest of 10 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is SFP-H10GB-CU1M at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 23mm; the stated power consumption is ≤0.1W; the jacket material is PVC (OFNR).
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 23mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 10G Ethernet. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep SFP-H10GB-CU50CM associated with 0.5m (2ft) throughout the order and receiving record.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco SFP-H10GB-CU50CM.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.