SFP-DD to QSFP56-100G-DAC-1M3FT 100G SFP-DD 2 x 50G PAM4 to QSFP56 2 x 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

SFP-DD to QSFP56-100G-DAC-1M3FT 100G SFP-DD 2 x 50G PAM4 to QSFP56 2 x 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

The SFP-DD to QSFP56-100G-DAC-1M3FT compatible assembly is a 100G DAC cable for Generic hosts, built in 1m (3ft) with SFP-DD to QSFP56. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: SFP-DD to QSFP56-100G-DAC-1M3FTHT Part Number: SFP-DD to QSFP56-100G-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP-DD to QSFP56
  • Fixed length and part number: 1m (3ft), SFP-DD to QSFP56-100G-DAC-1M3FT
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 17mm

Specifications

HT Part NumberSFP-DD to QSFP56-100G-DAC-1M3FT
ManufacturerHT
Form FactorSFP-DD to QSFP56
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length1m (3ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius17mm
Wire AWG30AWG
Max. Power Consumption0.1W
Modulation FormatSFP-DD-2x 50G-PAM4QSFP56-2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet, 128G Fibre Channel
ProtocolsSFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdQSFP56: SFF-8661, SFF-8636, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is SFP-DD-2x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdQSFP56: SFF-8661, SFF-8636, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), SFP-DD to QSFP56-100G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

SFP-DD to QSFP56-100G-DAC-1M3FT occupies the middle of this family between SFP-DD to QSFP56-100G-DAC-0.5M2FT at 0.5m (2ft) and SFP-DD to QSFP56-100G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 17mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 17mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my