SFP-DD to 2x SFP56-100G-DAC-3M10FT 100G SFP-DD 2 x 50G PAM4 to 2 x SFP56 50G PAM4 Passive Copper Twinax Cable, 3m (10ft)

SFP-DD to 2x SFP56-100G-DAC-3M10FT 100G SFP-DD 2 x 50G PAM4 to 2 x SFP56 50G PAM4 Passive Copper Twinax Cable, 3m (10ft)

Mixed-vendor installations require an exact compatibility identity at each host. This 3m (10ft) DAC cable is prepared for equipment expecting Generic SFP-DD to 2x SFP56-100G-DAC-3M10FT, providing 100G connectivity through SFP-DD to 2x SFP56. Equivalent-length brand links and separate length pages make it easier to document both ends of the connection correctly.

OEM Part Number: SFP-DD to 2x SFP56-100G-DAC-3M10FTHT Part Number: SFP-DD to 2x SFP56-100G-DAC-3M10FT

Product Highlights

  • HT-manufactured DAC assembly in 3m (10ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP-DD to 2x SFP56
  • Fixed length and part number: 3m (10ft), SFP-DD to 2x SFP56-100G-DAC-3M10FT
  • Cable construction: Passive Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 28.8mm

Specifications

HT Part NumberSFP-DD to 2x SFP56-100G-DAC-3M10FT
ManufacturerHT
Form FactorSFP-DD to 2x SFP56
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length3m (10ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius28.8mm
Wire AWG26AWG
Max. Power Consumption0.1W
Modulation FormatSFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet, 128G Fibre Channel
ProtocolsSFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28.8mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28.8mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The SFP-DD to 2x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

SFP-DD to 2x SFP56-100G-DAC-3M10FT is the longest of 4 verified length options in this family. Compared with SFP-DD to 2x SFP56-100G-DAC-2M7FT at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Quantity and any labeling instructions should be attached specifically to SFP-DD to 2x SFP56-100G-DAC-3M10FT.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. SFP-DD to 2x SFP56-100G-DAC-3M10FT refers here to 3m (10ft). Every other verified length has a separate part number and page in the length list.