SC UPC to Unterminated Fiber Pigtail, 12 Fibers, Unjacketed Color-Coded, OS2

SC UPC to Unterminated Fiber Pigtail, 12 Fibers, Unjacketed Color-Coded, OS2

Malaysian upgrade projects can use this configuration where its interface and fiber map align with both the installed cabling and the new hardware. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: SC UPC to Unterminated Fiber Pigtail, OS2 glass, with a factory-polished SC UPC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber route into a documented, testable port. Malaysian upgrade teams can use this detail to compare the new assembly with the installed cabling records.

Product Highlights

  • Color-coded for Easy Matching of 0.9mm Fiber to Be Spliced
  • Easy-strip 900µm Tight-buffered Coating
  • Precision Zirconia Ferrule Connectors Ensure Low Loss
  • Support Both Fusion and Mechanical Splicing
  • G.657.A1 Bend Insensitive Fiber & 10mm Min. Bend Radius

Specifications

Connector ASC UPC Simplex
Connector BUnterminated
Fiber Count12 Fibers
Fiber GradeG.657.A1
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Jacket Color12-Color
Cable JacketPVC (Unrated)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Connector Durability1000 Times
Attenuation at 1310nm0.36dB/km
Attenuation at 1550nm0.22dB/km
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-40 to 75°C (-40 to 167℉)
Storage Temperature-45 to 85°C (-49 to 185℉)
Connector TypeSC UPC Simplex to Unterminated
Fiber Count12 Fibers
Fiber GradeG.657.A1

Why pigtails remain the standard termination

A pigtail is half a connection: one end is a factory-completed connector, polished and tested under process control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the deployed cable brings the mating connector quality of the factory to a field route. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the route length is uncertain or the pathway is difficult to pre-measure.

Fusion splicing practice that protects the budget

A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. Malaysian upgrade teams can use this detail to compare the new assembly with the installed cabling records.

Color coding as a working discipline

Twelve fibers, twelve colors, one order: the TIA-598 sequence is the only thing standing between a tidy splice tray and a crossed plant. The strands in this set follow the standard sequence, meaning that the splicer matches colors between cable and pigtail without guesswork. When the documentation follows the same sequence, a fault on position seven months from now is found in minutes rather than traced strand by strand.

Keeping twelve-fiber splices organized

Multi-fiber splicing rewards method: whole one color fully - strip, clean, cleave, splice, sleeve - before starting the next, and dress every finished strand into the tray in sequence. The color-coded set makes the pairing unambiguous, and the tray stays readable for the next technician who opens it. A tray that reads clearly and consistently is a tray that gets re-entered without new faults.

Unjacketed and bunch constructions compared

The unjacketed color-coded set presents twelve independent 0.9mm strands for direct tray work - the lightest construction and the easiest to dress. The bunch construction gathers the twelve strands under a shared jacket that breaks out near the mating connector end, adding handling protection on the route between the mounted panel and the tray. Choose unjacketed where the strands stay inside a protected enclosure; choose bunch where the finished product crosses open space between frames.

Bend-insensitive glass in dense trays

Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the link margin intact after the tenth tray opening, not just at commissioning. Malaysian upgrade teams can use this detail to compare the new assembly with the installed cabling records.

A splicing workflow that scales

Productive termination crews work to a fixed routine: mount the tray, dress the completed cable, splice the pigtails color by color, protect every joint, test every completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame position in a predictable time, and the test record maps cleanly onto the documentation. The consistency also makes quality auditable - same materials, same sequence, same pass criteria across each site.

Sparing and kit planning for termination work

Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame position, keep spare strands capped and bagged, and record which set went into which tray so replacement stock can generally be ordered to the identical specification.

Selecting the right pigtail for the job

Five decisions define the order: the mating connector family must agree with the mounted panel, the polish must agree with the plant, the fiber mode must agree with the completed cable, the construction must agree with the route, and the count must agree with the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the need sits outside the standard configurations, the project-specific platforms cover the remaining combinations.

Testing and Inspection Practice

Each pigtail is optically tested before packing: insertion loss and return loss are verified on every terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results available on request.

Ordering and Customization Support

Refer to this pigtail by connector, polish, fiber mode, fiber count and construction when seeking a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packing - send the need with the inquiry and the factory will determine the manufacturable specification. For Malaysian upgrades, our team can compare the requested build with the existing environment before production begins.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my