Where a network combines several equipment vendors, select this assembly by the Generic QSFP56 to QSFP56-200G-ACC-5M16FT requirement rather than by its connector shape alone. This page covers the 5m (16ft) ACC version at 200G, including its QSFP56 to QSFP56 configuration, related brand identities and factory operating checks.
OEM Part Number: QSFP56 to QSFP56-200G-ACC-5M16FTHT Part Number: QSFP56 to QSFP56-200G-ACC-5M16FT
| HT Part Number | QSFP56 to QSFP56-200G-ACC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP56 to QSFP56 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 5m (16ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 40mm |
| Max. Power Consumption | 1.5W Per End |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636 |
The rated power consumption is 1.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40mm; the stated power consumption is 1.5W Per End; the jacket material is PVC (OFNR).
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 40mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
The 5m (16ft) length gives QSFP56 to QSFP56-200G-ACC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
QSFP56 to QSFP56-200G-ACC-5M16FT occupies the middle of this family between QSFP56 to QSFP56-200G-ACC-4M13FT at 4m (13ft) and QSFP56 to QSFP56-200G-ACC-7M23FT at 7m (23ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Quantity and any labeling instructions should be attached specifically to QSFP56 to QSFP56-200G-ACC-5M16FT.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.