QSFP28 to SFP28-100G-DAC-1.5M5FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1.5m (5ft)

QSFP28 to SFP28-100G-DAC-1.5M5FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1.5m (5ft)

The QSFP28 to SFP28-100G-DAC-1.5M5FT compatible assembly is a 100G DAC cable for Generic hosts, built in 1.5m (5ft) with QSFP28 to SFP28. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: QSFP28 to SFP28-100G-DAC-1.5M5FTHT Part Number: QSFP28 to SFP28-100G-DAC-1.5M5FT

Product Highlights

  • HT-manufactured DAC assembly in 1.5m (5ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to SFP28
  • Fixed length and part number: 1.5m (5ft), QSFP28 to SFP28-100G-DAC-1.5M5FT
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.125W
  • Minimum bend radius: 60mm

Specifications

HT Part NumberQSFP28 to SFP28-100G-DAC-1.5M5FT
ManufacturerHT
Form FactorQSFP28 to SFP28
Max Data Rate100Gbps
Cable TypePassive Twinax
Cable Length1.5m (5ft)
Wire AWG30AWG
Minimum Bend Radius60mm
Power Consumption≤0.125W
Power Supply3.3V
MTBF=50 Million Hours
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
MediaCopper
Application100G to 4x 25G Ethernet, Data Centers
ProtocolsIEEE 802.3, QSFP28 MSA, SFF-8665

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives QSFP28 to SFP28-100G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

QSFP28 to SFP28-100G-DAC-1.5M5FT occupies the middle of this family between QSFP28 to SFP28-100G-DAC-0.5M2FT at 0.5m (2ft) and QSFP28 to SFP28-100G-DAC-2M7FT at 2m (7ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 60mm; the stated power consumption is ≤0.125W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Quantity and any labeling instructions should be attached specifically to QSFP28 to SFP28-100G-DAC-1.5M5FT.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. QSFP28 to SFP28-100G-DAC-1.5M5FT refers here to 1.5m (5ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my