The QSFP+ to SFP+-40G-ACC-9M29FT compatible assembly is a 40G ACC cable for Generic hosts, built in 9m (29ft) with QSFP+ to SFP+. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.
OEM Part Number: QSFP+ to SFP+-40G-ACC-9M29FTHT Part Number: QSFP+ to SFP+-40G-ACC-9M29FT
| HT Part Number | QSFP+ to SFP+-40G-ACC-9M29FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP+ to SFP+ |
| Max Data Rate | 40Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 9m (29ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 44.5mm |
| Power Consumption | ≤1.8W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8431, SFF-8432, SFF-8472 SFP+ MSA, SFF-8436 QSFP+ MSA |
The rated power consumption is ≤1.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
QSFP+ to SFP+-40G-ACC-9M29FT is the longest of 5 verified length options in this family. Compared with QSFP+ to SFP+-40G-ACC-7M23FT at 7m (23ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 44.5mm; the stated power consumption is ≤1.8W; the jacket material is PVC (OFNR).
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 44.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8431, SFF-8432, SFF-8472 SFP+ MSA, SFF-8436 QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP+ to SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A 9m (29ft) run can remain tidy when its pathway and service allowance are planned together. Keep the complete copper assembly and both connector housings away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. The next shorter verified assembly is QSFP+ to SFP+-40G-ACC-7M23FT at 7m (23ft), which is the better comparison when the managed route leaves substantial unused cable.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 9m (29ft); another length must be quoted under its corresponding part number.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.