QSFP-DD to 2x QSFP28-200G-DAC-3M10FT 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

QSFP-DD to 2x QSFP28-200G-DAC-3M10FT 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

The QSFP-DD to 2x QSFP28-200G-DAC-3M10FT compatible assembly is a 200G DAC cable for Generic hosts, built in 3m (10ft) with QSFP-DD to 2x QSFP28. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: QSFP-DD to 2x QSFP28-200G-DAC-3M10FTHT Part Number: QSFP-DD to 2x QSFP28-200G-DAC-3M10FT

Product Highlights

  • HT-manufactured DAC assembly in 3m (10ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 2x QSFP28
  • Fixed length and part number: 3m (10ft), QSFP-DD to 2x QSFP28-200G-DAC-3M10FT
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
  • Minimum bend radius: 35mm

Specifications

HT Part NumberQSFP-DD to 2x QSFP28-200G-DAC-3M10FT
ManufacturerHT
Form FactorQSFP-DD to 2x QSFP28
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius35mm
Wire AWG28AWG
Cable Length3m (10ft)
Jacket MaterialPVC
Max. Power Consumption0.1W (QSFP-DD End)0.1W (QSFP28 Per End)
Modulation FormatQSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 25G-NRZQSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP28 Per End); the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8661, IEEE 802.3bs-200GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 2x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

QSFP-DD to 2x QSFP28-200G-DAC-3M10FT is the longest of 4 verified length options in this family. Compared with QSFP-DD to 2x QSFP28-200G-DAC-2M7FT at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my