Juniper Networks QDD-8x50G-2.5M Compatible 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 2.5m (8ft)

Juniper Networks QDD-8x50G-2.5M Compatible 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 2.5m (8ft)

Where a network combines several equipment vendors, select this assembly by the Juniper Networks QDD-8x50G-2.5M requirement rather than by its connector shape alone. This page covers the 2.5m (8ft) DAC version at 400G, including its QSFP-DD to 8x SFP56 configuration, related brand identities and factory operating checks.

OEM Part Number: QDD-8x50G-2.5MHT Part Number: QDD-8x50G-2.5M

Product Highlights

  • Compatible alternative to Juniper Networks QDD-8x50G-2.5M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 8x SFP56
  • Fixed length and part number: 2.5m (8ft), QDD-8x50G-2.5M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (SFP56 Per End)
  • Minimum bend radius: 39.5mm

Specifications

HT Part NumberQDD-8x50G-2.5M
Juniper Networks CompatibleQDD-8x50G-2.5M
ManufacturerHT
Form FactorQSFP-DD to 8x SFP56
Max. Data Rate400Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius39.5mm
Wire AWG28AWG
Cable Length2.5m (8ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP-DD End)0.1W (SFP56 Per End)
Modulation FormatQSFP-DD-8x 50G-PAM4SFP56-50G-PAM4
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8432, IEEE 802.3bs-400GAUI-8, IEEE802.3cd-50GAUI-1, CMIS 4.0, SFF-8472

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4SFP56-50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 39.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-400GAUI-8, IEEE802.3cd-50GAUI-1, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 8x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that QDD-8x50G-2.5M reaches both ports without tension at either connector.

Position Within the Length Range

QDD-8x50G-2.5M occupies the middle of this family between QDD-8x50G-2M at 2m (7ft) and QDD-8x50G-3M at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 39.5mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (SFP56 Per End); the jacket material is PVC (OFNR).

Juniper Networks Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 2.5m (8ft); another length must be quoted under its corresponding part number.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-8x50G-2.5M.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.