
Mixed-vendor installations require an exact compatibility identity at each host. This 0.5m (2ft) DAC cable is prepared for equipment expecting Juniper Networks QDD-800G-DAC-0.5M, providing 800G connectivity through QSFP-DD to QSFP-DD. Equivalent-length brand links and separate length pages make it easier to document both ends of the connection correctly.
OEM Part Number: QDD-800G-DAC-0.5MHT Part Number: QDD-800G-DAC-0.5M
| HT Part Number | QDD-800G-DAC-0.5M |
|---|---|
| Juniper Networks Compatible | QDD-800G-DAC-0.5M |
| Manufacturer | HT |
| Form Factor | QSFP-DD to QSFP-DD |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive DAC |
| Cable Length | 0.5m (2ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 69mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 0.005W Per End |
| Modulation Format | 8x 100G-PAM4 |
| Commercial TemperatureRange | 0 to 70°C (32 to 158°F) |
| Application | 800G Ethernet |
| Protocols | QSFP-DD MSA, CMIS Rev4.0, IEEE 802.3ck |
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 69mm; the stated power consumption is 0.005W Per End; the jacket material is PVC (OFNR).
The listed modulation format is 8x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The rated power consumption is 0.005W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 69mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G Ethernet. Listed interface and protocol references include QSFP-DD MSA, CMIS Rev4.0, IEEE 802.3ck. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing QDD-800G-DAC-0.5M; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
QDD-800G-DAC-0.5M is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QDD-800G-DAC-1M at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep QDD-800G-DAC-0.5M associated with 0.5m (2ft) throughout the order and receiving record.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-800G-DAC-0.5M.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.