Juniper Networks QDD-400G-DAC-1.5M Compatible 400G QSFP-DD 8 x 50G PAM4 Passive Copper Twinax Cable, 1.5m (5ft)

Juniper Networks QDD-400G-DAC-1.5M Compatible 400G QSFP-DD 8 x 50G PAM4 Passive Copper Twinax Cable, 1.5m (5ft)

The QDD-400G-DAC-1.5M compatible assembly is a 400G DAC cable for Juniper Networks hosts, built in 1.5m (5ft) with QSFP-DD to QSFP-DD. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: QDD-400G-DAC-1.5MHT Part Number: QDD-400G-DAC-1.5M

Product Highlights

  • Compatible alternative to Juniper Networks QDD-400G-DAC-1.5M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 1.5m (5ft), QDD-400G-DAC-1.5M
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W Per End
  • Minimum bend radius: 33mm

Specifications

HT Part NumberQDD-400G-DAC-1.5M
Juniper Networks CompatibleQDD-400G-DAC-1.5M
ManufacturerHT
Form FactorQSFP-DD to QSFP-DD
Max. Data Rate400Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length1.5m (5ft)
Wire AWG30AWG
Minimum Bend Radius33mm
Max. Power Consumption0.1W Per End
Jacket MaterialPET
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation Format8x 50Gbps PAM4
Application400G Ethernet
ProtocolsIEEE 802.3cd, QSFP-DD MSA, CMIS 4.0

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Signal and Lane Configuration

The listed modulation format is 8x 50Gbps PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 33mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include IEEE 802.3cd, QSFP-DD MSA, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives QDD-400G-DAC-1.5M useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

QDD-400G-DAC-1.5M occupies the middle of this family between QDD-400G-DAC-1M at 1m (3ft) and QDD-400G-DAC-2M at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 33mm; the stated power consumption is 0.1W Per End; the jacket material is PET.

Juniper Networks Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Quantity and any labeling instructions should be attached specifically to QDD-400G-DAC-1.5M.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-400G-DAC-1.5M.

Does this order code cover multiple lengths?

No. QDD-400G-DAC-1.5M refers here to 1.5m (5ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.