Where a network combines several equipment vendors, select this assembly by the Cisco Q56-200-CU2M requirement rather than by its connector shape alone. This page covers the 2m (7ft) DAC version at 200G, including its QSFP56 to QSFP56 configuration, related brand identities and factory operating checks.
OEM Part Number: Q56-200-CU2MHT Part Number: Q56-200-CU2M
| HT Part Number | Q56-200-CU2M |
|---|---|
| Cisco Compatible | Q56-200-CU2M |
| Manufacturer | HT |
| Form Factor | QSFP56 to QSFP56 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 2m (7ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 39mm |
| Max. Power Consumption | 0.03W Per End |
| Jacket Material | PVC |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE802.3cd, SFF-8436 |
The rated power consumption is 0.03W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Q56-200-CU2M occupies the middle of this family between Q56-200-CU150CM at 1.5m (5ft) and Q56-200-CU3M at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 39mm; the stated power consumption is 0.03W Per End; the jacket material is PVC.
This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 39mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE802.3cd, SFF-8436. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Q56-200-CU2M provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco Q56-200-CU2M.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.