OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT 1.6T OSFP224 8 x 200G PAM4 RHS/Flat Top Active Copper Twinax Cable, 2m (7ft)

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT 1.6T OSFP224 8 x 200G PAM4 RHS/Flat Top Active Copper Twinax Cable, 2m (7ft)

The OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT compatible assembly is a 1.6T ACC cable for Generic hosts, built in 2m (7ft) with OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top). It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FTHT Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT

Product Highlights

  • HT-manufactured ACC assembly in 2m (7ft)
  • 1.6T connectivity at 1600Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)
  • Fixed length and part number: 2m (7ft), OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 25AWG
  • Maximum power consumption: 2.5W Per End
  • Minimum bend radius: 60mm

Specifications

HT Part NumberOSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)
Max. Data Rate1600Gbps
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length2m (7ft)
Jacket MaterialLSZH
Minimum Bend Radius60mm
Wire AWG25AWG
Max. Power Consumption2.5W Per End
Modulation Format8x 200G-PAM4 to 8x 200G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application1.6T Ethernet
ProtocolsOSFP Rev 5.2, CMIS 5.0, IEEE 802.3df and 802.3dj

Signal and Lane Configuration

The listed modulation format is 8x 200G-PAM4 to 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 1.6T Ethernet. Listed interface and protocol references include OSFP Rev 5.2, CMIS 5.0, IEEE 802.3df and 802.3dj. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT is the longest of 2 verified length options in this family. Compared with OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT at 1m (3ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 25AWG; the minimum bend radius is 60mm; the stated power consumption is 2.5W Per End; the jacket material is LSZH.

Power and Thermal Planning

The rated power consumption is 2.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 25AWG conductors, LSZH jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my