OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT 1.6T OSFP224 8 x 200G PAM4 IHS Finned Top Passive Copper Twinax Cable, 1m (3ft)

OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT 1.6T OSFP224 8 x 200G PAM4 IHS Finned Top Passive Copper Twinax Cable, 1m (3ft)

The OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT compatible assembly is a 1.6T DAC cable for Generic hosts, built in 1m (3ft) with OSFP (IHS Finned Top) to OSFP (IHS Finned Top). It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FTHT Part Number: OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 1.6T connectivity at 1600Gbps
  • Interface configuration: OSFP (IHS Finned Top) to OSFP (IHS Finned Top)
  • Fixed length and part number: 1m (3ft), OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT
  • Cable construction: Passive DAC
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W Per End
  • Minimum bend radius: 55mm

Specifications

HT Part NumberOSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT
ManufacturerHT
Form FactorOSFP (IHS Finned Top) to OSFP (IHS Finned Top)
Max. Data Rate1600Gbps
MediaCopper
Cable TypePassive DAC
Cable Length1m (3ft)
Jacket MaterialPET
Minimum Bend Radius55mm
Wire AWG26AWG
Max. Power Consumption0.1W Per End
Modulation Format8x 200G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application1.6T Ethernet
ProtocolsOSFP MSA, IEEE 802.3

Signal and Lane Configuration

The listed modulation format is 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 55mm; the stated power consumption is 0.1W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PET jacket, minimum bend radius 55mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 1.6T Ethernet. Listed interface and protocol references include OSFP MSA, IEEE 802.3. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT is the longest of 2 verified length options in this family. Compared with OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-0.5M2FT at 0.5m (2ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Quantity and any labeling instructions should be attached specifically to OSFP (IHS Finned Top) to OSFP (IHS Finned Top)-1.6T-DAC-1M3FT.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.