OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT 400G OSFP IHS/Finned Top to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 3m (10ft)

OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT 400G OSFP IHS/Finned Top to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 3m (10ft)

The OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT compatible assembly is a 400G DAC cable for Generic hosts, built in 3m (10ft) with OSFP (IHS/Finned Top) to 4x QSFP56. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FTHT Part Number: OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT

Product Highlights

  • HT-manufactured DAC assembly in 3m (10ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 4x QSFP56
  • Fixed length and part number: 3m (10ft), OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT
  • Cable construction: Passive Twinax
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (OSFP End) 0.1W (QSFP56 Per End)
  • Minimum bend radius: 30mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 4x QSFP56
Max. Data Rate400Gbps
Cable Length3m (10ft)
Wire AWG28AWG
Minimum Bend Radius30mm
Max. Power Consumption0.1W (OSFP End) 0.1W (QSFP56 Per End)
MediaCopper
Cable TypePassive Twinax
Modulation Format8x 50G-PAM4 to Quad 2x 50G-PAM4
Jacket MaterialPVC (OFNR)
Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, IEEE 802.3cd, CMIS v4.0

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4 to Quad 2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3cd, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT is the longest of 6 verified length options in this family. Compared with OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT at 2.5m (8ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 30mm; the stated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End); the jacket material is PVC (OFNR).

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT associated with 3m (10ft) throughout the order and receiving record.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.