Mixed-vendor installations require an exact compatibility identity at each host. This 5m (16ft) ACC cable is prepared for equipment expecting Generic OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-5M16FT, providing 800G connectivity through OSFP (IHS/Finned Top) to 2x QSFP112. Equivalent-length brand links and separate length pages make it easier to document both ends of the connection correctly.
OEM Part Number: OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-5M16FTHT Part Number: OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-5M16FT
| HT Part Number | OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 2x QSFP112 |
| Max. Data Rate | 850Gbps (8x 106.25Gbps) |
| Media | Copper |
| Cable Type | Active Breakout DAC (ACC) |
| Cable Length | 5m (16ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 40mm |
| Max. Power Consumption | 1.5W (OSFP End)0.6W (QSFP112 Per End) |
| Jacket Material | PET |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 to Dual 4x100G-PAM4 |
| Application | 800G/400G Ethernet |
| Protocols | CMIS 5.0, IEEE 802.3ck, OSFP MSA Rev5.0, Q112 MSA |
The listed modulation format is 8x100G-PAM4 to Dual 4x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The 5m (16ft) length gives OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-5M16FT is the longest of 5 verified length options in this family. Compared with OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-4M13FT at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 40mm; the stated power consumption is 1.5W (OSFP End)0.6W (QSFP112 Per End); the jacket material is PET.
The rated power consumption is 1.5W (OSFP End)0.6W (QSFP112 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 40mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/400G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP MSA Rev5.0, Q112 MSA. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 2x QSFP112 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-5M16FT associated with 5m (16ft) throughout the order and receiving record.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
No. OSFP (IHS/Finned Top) to 2x QSFP112-800G-ACC-5M16FT refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.