OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Electrical Copper Breakout Cable, 4m (13ft)

OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Electrical Copper Breakout Cable, 4m (13ft)

The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT compatible assembly is a 800G AEC cable for Generic hosts, built in 4m (13ft) with OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top). It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FTHT Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT

Product Highlights

  • HT-manufactured AEC assembly in 4m (13ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)
  • Fixed length and part number: 4m (13ft), OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT
  • Cable construction: Active Breakout DAC (AEC)
  • Conductor specification: 28AWG
  • Maximum power consumption: 12W (800G End)10W (400G Per End)
  • Minimum bend radius: 38mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)
Max. Data Rate800Gbps
MediaCopper
Cable TypeActive Breakout DAC (AEC)
Cable Length4m (13ft)
Jacket MaterialPET
Minimum Bend Radius38mm
Wire AWG28AWG
Max. Power Consumption12W (800G End)10W (400G Per End)
Modulation Format8x100G-PAM4 to Dual 4x100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G/400G Ethernet
ProtocolsOSFP MSA Rev5.1, IEEE 802.3ck, CMIS 5.0

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4 to Dual 4x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

The 4m (13ft) length gives OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the AEC specification and host support must still match the intended link.

Position Within the Length Range

OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT occupies the middle of this family between OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-3M10FT at 3m (10ft) and OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT at 5m (16ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 38mm; the stated power consumption is 12W (800G End)10W (400G Per End); the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 12W (800G End)10W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PET jacket, minimum bend radius 38mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA Rev5.1, IEEE 802.3ck, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Generic Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT associated with 4m (13ft) throughout the order and receiving record.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my