Mixed-vendor installations require an exact compatibility identity at each host. This 30m (98ft) AOC cable is prepared for equipment expecting NVIDIA/Mellanox MFA7U10-H030, providing 400G connectivity through OSFP to 2× QSFP56. Equivalent-length brand links and separate length pages make it easier to document both ends of the connection correctly.
OEM Part Number: MFA7U10-H030HT Part Number: MFA7U10-H030
| HT Part Number | MFA7U10-H030 |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MFA7U10-H030 |
| Manufacturer | HT |
| Form Factor | OSFP to 2× QSFP56 |
| Max. Data Rate | 400Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 30m (98ft) |
| Jacket Material | OFNP |
| Cable Type | Breakout AOC |
| Receiver Type | PIN |
| Transmitter Type | VCSEL |
| Wavelength | 850nm |
| Wire AWG | 30AWG |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Max. Power Consumption | 10W (OSFP End) 5.5W (QSFP56 Per End) |
| Protocols | OSFP Rev. 5.0, SFF-8679, SFF-8661, SFF-8636, CMIS Rev 4.0, IEEE 802.3cd |
| Modulation Format | OSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4 |
The listed modulation format is OSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Extended reach changes the installation checks for MFA7U10-H030. Confirm that 30m (98ft) follows the intended route without tension, then verify that intermediate supports do not squeeze the jacket or hide the connectors behind adjacent cables. Both hosts must still match the stated interface and lane configuration. The next shorter verified assembly is MFA7U10-H020 at 20m (66ft), which is the better comparison when the managed route leaves substantial unused cable.
MFA7U10-H030 is the longest of 5 verified length options in this family. Compared with MFA7U10-H020 at 20m (66ft), it provides 10m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End); the jacket material is OFNP.
The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP Rev. 5.0, SFF-8679, SFF-8661, SFF-8636, CMIS Rev 4.0, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP to 2× QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep MFA7U10-H030 associated with 30m (98ft) throughout the order and receiving record.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFA7U10-H030.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.