NVIDIA/Mellanox MCP7H70-V002R26 Compatible 200G QSFP56 4 x 50G PAM4 to 4 x 50G SFP56 50G PAM4 Ethernet Passive Copper Breakout Cable, 2m (7ft)

NVIDIA/Mellanox MCP7H70-V002R26 Compatible 200G QSFP56 4 x 50G PAM4 to 4 x 50G SFP56 50G PAM4 Ethernet Passive Copper Breakout Cable, 2m (7ft)

The MCP7H70-V002R26 compatible assembly is a 200G DAC cable for NVIDIA/Mellanox hosts, built in 2m (7ft) with QSFP56 to 4x SFP56. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: MCP7H70-V002R26HT Part Number: MCP7H70-V002R26

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCP7H70-V002R26
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to 4x SFP56
  • Fixed length and part number: 2m (7ft), MCP7H70-V002R26
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W (QSFP56 End)0.1W (SFP56 Per End)
  • Minimum bend radius: 35mm

Specifications

HT Part NumberMCP7H70-V002R26
NVIDIA/Mellanox EthernetCompatibleMCP7H70-V002R26
ManufacturerHT
Form FactorQSFP56 to 4x SFP56
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius35mm
Wire AWG26AWG
Cable Length2m (7ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP56 End)0.1W (SFP56 Per End)
Modulation FormatQSFP56-4x 50G-PAM4SFP56-50G-PAM4
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsSFF-8661, SFF-8432, IEEE 802.3bs-200GAUI-4, IEEE802.3cd-50GAUI-1, SFP-8636, SFF-8472

Signal and Lane Configuration

The listed modulation format is QSFP56-4x 50G-PAM4SFP56-50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

MCP7H70-V002R26 provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

MCP7H70-V002R26 occupies the middle of this family between MCP7H70-V001R30 at 1m (3ft) and MCP7H70-V003R26 at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP56 End)0.1W (SFP56 Per End); the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP56 End)0.1W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8661, SFF-8432, IEEE 802.3bs-200GAUI-4, IEEE802.3cd-50GAUI-1, SFP-8636, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP56 to 4x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

NVIDIA/Mellanox Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7H70-V002R26.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my