NVIDIA/Mellanox MCA7J70-N001 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top Ethernet Active Copper Breakout Cable, 1m (3ft)

NVIDIA/Mellanox MCA7J70-N001 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top Ethernet Active Copper Breakout Cable, 1m (3ft)

Where a network combines several equipment vendors, select this assembly by the NVIDIA/Mellanox MCA7J70-N001 requirement rather than by its connector shape alone. This page covers the 1m (3ft) ACC version at 800G, including its OSFP (IHS/Finned Top) to 4x OSFP (RHS/Flat Top) configuration, related brand identities and factory operating checks.

OEM Part Number: MCA7J70-N001HT Part Number: MCA7J70-N001

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCA7J70-N001
  • 800G connectivity at 850Gbps (8x 106.25Gbps)
  • Interface configuration: OSFP (IHS/Finned Top) to 4x OSFP (RHS/Flat Top)
  • Fixed length and part number: 1m (3ft), MCA7J70-N001
  • Cable construction: Active Breakout DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: 1.7W (800G End)0.3W (200G Per End)
  • Minimum bend radius: 23mm

Specifications

HT Part NumberMCA7J70-N001
NVIDIA/Mellanox Ethernet CompatibleMCA7J70-N001
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 4x OSFP (RHS/Flat Top)
Max. Data Rate850Gbps (8x 106.25Gbps)
MediaCopper
Cable TypeActive Breakout DAC (ACC)
Cable Length1m (3ft)
Wire AWG30AWG
Minimum Bend Radius23mm
Max. Power Consumption1.7W (800G End)0.3W (200G Per End)
Jacket MaterialPET
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation Format8x100G-PAM4 to Quad 2x100G-PAM4
Application800G/200G Ethernet
ProtocolsCMIS 5.0, IEEE 802.3ck, OSFP MSA Rev 5.0

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4 to Quad 2x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

At 1m (3ft), MCA7J70-N001 is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

MCA7J70-N001 is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is MCA7J70-N002 at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 23mm; the stated power consumption is 1.7W (800G End)0.3W (200G Per End); the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 1.7W (800G End)0.3W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 23mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G/200G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP MSA Rev 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 4x OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

NVIDIA/Mellanox Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Quantity and any labeling instructions should be attached specifically to MCA7J70-N001.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA7J70-N001.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my