LC UPC to SC UPC Duplex OM4 Fiber Patch Cable

LC UPC to SC UPC Duplex OM4 Fiber Patch Cable

Malaysian upgrade projects can use this configuration where its interface and fiber map align with both the installed cabling and the new hardware. This OM4 fiber patch cable carries a LC UPC interface on one end and a SC UPC interface on the other, factory terminated on OM4 glass and optically tested as a whole assembly. The duplex zipcord construction keeps the transmit and receive strands paired in one assembly for fast, error-free patching.

Product Highlights

  • Bend Insensitive Fiber with 7.5mm Min. Bend Radius
  • Precision Zirconia Ferrule Connectors Ensure Low Loss
  • Flame-Retardant Riser (OFNR) for Vertical and Floor-to-Floor Installations
  • Color-Coded Cable Jacket for Easy Identification
  • Duplex Zipcord Construction Reduces Risk of Damage from Crimping

Specifications

Connector ALC UPC Duplex
Connector BSC UPC Duplex
Fiber Count2 Fibers
Fiber GradeBend Insensitive Fiber
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Flame RatingRiser (OFNR)
Cable Outside Diameter (OD)2.0mm
PolarityA (Tx) to B (Rx)
Cable TypeTight-Buffered
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Connector Durability1000 times
Tensile Strength90/150N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥30dB
Attenuation at 850nm≤3.5dB/km
Attenuation at 1300nm≤1.5dB/km
Operating Temperature-10 to 70°C (14 to 158℉)
Storage Temperature-20 to 70°C (-4 to 158℉)

Polarity and pairing in duplex links

A duplex jumper is two fibers with a defined A-to-B crossover. Getting polarity right at the cord level keeps the channel consistent end to end, which is why these assemblies are built and tested as a pair rather than as two distinct strands.

Multimode reach for the data hall

This OM4 assembly serves the short-reach fabric of the data center: 10G and 25G server uplinks, 40G and 100G SR4 spine links and the inter-row runs between them. On OM4 glass, 10G Ethernet holds to 400 meters and 100G SR4 to 100 meters, which covers the overwhelming majority of in-hall routes with margin to spare. Malaysian upgrade teams can use this detail to compare the new assembly with the installed cabling records.

Length Options

Normal length options cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), with project-specific length available beyond the list. Specifying the measured route length keeps the slack out of the manager and the strain off the relevant connectors.

Quality Control and Testing

Each finished assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on every cable, and end-face geometry is inspected for consistent physical contact. The completed cable ships with dust caps on the two connectors and the test result available on request.

Ordering and Factory Support

Refer to this configuration by connector pair, fiber mode and length when seeking a quotation. For configurations outside the listed options, mixed connector families, jackets, labelling or project packing, send the need with the inquiry and the factory will determine the build before the product is built. For Malaysian upgrades, our team can compare the requested build with the existing environment before production begins.