HPE H3C JG327A Compatible 40G QSFP+ Passive Copper Cable, 3m (10ft)

HPE H3C JG327A Compatible 40G QSFP+ Passive Copper Cable, 3m (10ft)

Mixed-vendor installations require an exact compatibility identity at each host. This 3m (10ft) DAC cable is prepared for equipment expecting HPE H3C JG327A, providing 40G connectivity through QSFP+ to QSFP+. Equivalent-length brand links and separate length pages make it easier to document both ends of the connection correctly.

OEM Part Number: JG327AHT Part Number: JG327A

Product Highlights

  • Compatible alternative to HPE H3C JG327A
  • 40G connectivity at 40Gbps
  • Interface configuration: QSFP+ to QSFP+
  • Fixed length and part number: 3m (10ft), JG327A
  • Conductor specification: 30AWG
  • Minimum bend radius: 35mm

Specifications

HT Part NumberJG327A
H3C CompatibleJG327A
ManufacturerHT
Connector TypeQSFP+ to QSFP+
Max Data Rate40Gbps
Minimum Bend Radius35mm
Wire AWG30AWG
Cable Length3m (9.84ft)
Jacket MaterialPVC (OFNR)
Temperature0 to 70°C (32 to 158°F)
ProtocolsSFF-8436, QSFP+ MSA and IEEE 802.3ba

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

JG327A is the longest of 2 verified length options in this family. Compared with JG326A at 1m (3ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 35mm; the jacket material is PVC (OFNR).

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, QSFP+ MSA and IEEE 802.3ba. Confirm that the host firmware and port configuration support the same operating mode.

HPE H3C Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep JG327A associated with 3m (10ft) throughout the order and receiving record.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original HPE H3C cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies HPE H3C JG327A.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.