Juniper Networks EX-SFP-10GE-DAC-7M Compatible 10G SFP+ Passive Copper Twinax Cable, 7m (23ft)

Juniper Networks EX-SFP-10GE-DAC-7M Compatible 10G SFP+ Passive Copper Twinax Cable, 7m (23ft)

The EX-SFP-10GE-DAC-7M compatible assembly is a 10G DAC cable for Juniper Networks hosts, built in 7m (23ft) with SFP+ to SFP+. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: EX-SFP-10GE-DAC-7MHT Part Number: EX-SFP-10GE-DAC-7M

Product Highlights

  • Compatible alternative to Juniper Networks EX-SFP-10GE-DAC-7M
  • 10G connectivity at 10Gbps
  • Interface configuration: SFP+ to SFP+
  • Fixed length and part number: 7m (23ft), EX-SFP-10GE-DAC-7M
  • Cable construction: Passive Twinax
  • Conductor specification: 24AWG
  • Maximum power consumption: ≤0.1W
  • Minimum bend radius: 30mm

Specifications

HT Part NumberEX-SFP-10GE-DAC-7M
Juniper CompatibleSFP-H10GB-CU7M
ManufacturerHT
Connector TypeSFP+ to SFP+
Max Data Rate10Gbps
MediaCopper
Power Supply3.3V
Minimum Bend Radius30mm
Wire AWG24AWG
Cable Length7m (22.97ft)
Jacket MaterialPVC (OFNR)
Cable TypePassive Twinax
Temperature0 to 70°C (32 to 158°F)
Power Consumption≤0.1W
Application10G Ethernet
Protocols1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Cable Construction and Routing

This assembly uses 24AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 10G Ethernet. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

A 7m (23ft) run can remain tidy when its pathway and service allowance are planned together. Keep the complete copper assembly and both connector housings away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. The next shorter verified assembly is EX-SFP-10GE-DAC-6M at 6m (20ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

EX-SFP-10GE-DAC-7M is the longest of 10 verified length options in this family. Compared with EX-SFP-10GE-DAC-6M at 6m (20ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 24AWG; the minimum bend radius is 30mm; the stated power consumption is ≤0.1W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Juniper Networks Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep EX-SFP-10GE-DAC-7M associated with 7m (23ft) throughout the order and receiving record.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks EX-SFP-10GE-DAC-7M.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.