Mixed-vendor installations require an exact compatibility identity at each host. This 1m (3ft) DAC cable is prepared for equipment expecting Dell (DE) DAC-Q28-4SFP28-25G-1M, providing 100G connectivity through QSFP28 to SFP28. Equivalent-length brand links and separate length pages make it easier to document both ends of the connection correctly.
OEM Part Number: DAC-Q28-4SFP28-25G-1MHT Part Number: DAC-Q28-4SFP28-25G-1M
| HT Part Number | DAC-Q28-4SFP28-25G-1M |
|---|---|
| Dell (DE) Compatible | DAC-Q28-4SFP28-25G-1M |
| Manufacturer | HT |
| Form Factor | QSFP28 to SFP28 |
| Max Data Rate | 100Gbps |
| Cable Type | Passive Twinax |
| Cable Length | 1m (3ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 60mm |
| Power Consumption | ≤0.125W |
| Power Supply | 3.3V |
| MTBF | =50 Million Hours |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ |
| Media | Copper |
| Application | 100G to 4x 25G Ethernet, Data Centers |
| Protocols | IEEE 802.3, QSFP28 MSA, SFF-8665 |
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
At 1m (3ft), DAC-Q28-4SFP28-25G-1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
DAC-Q28-4SFP28-25G-1M occupies the middle of this family between DAC-Q28-4SFP28-25G-0.5M at 0.5m (2ft) and DAC-Q28-4SFP28-25G-1.5M at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 60mm; the stated power consumption is ≤0.125W; the jacket material is PVC (OFNR).
The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.
Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.
No. It is an HT-manufactured compatible alternative for equipment that specifies Dell (DE) DAC-Q28-4SFP28-25G-1M.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.