This 8 Fibers MTP® Elite Female jumper is factory terminated and fully tested in our own facility, built on OM4 50/125μm fiber with a Plenum (OFNP) jacket. It is designed for high density patching inside data center cabinets, where pre-terminated cabling saves hours of field splicing and keeps polarity under control from day one.
Available lengths are 1m (3ft) and 3m (10ft). We can also produce any intermediate or longer length to order, with your choice of labeling and packaging.
| Part Number | 8FMTPOM4 |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MTP® Elite Female (Non-Pinned) |
| Connector B | US Conec MTP® Elite Female (Non-Pinned) |
| Fiber Mode | OM4 50/125μm |
| Wavelength | 850/1300nm |
| Polish Type | UPC to UPC |
| Polarity | Type B |
| Cable Jacket | Plenum (OFNP) |
| Fiber Count | 8 Fibers |
| Glass Fiber | Bend Insensitive Fiber |
| Cable Outside Diameter (OD) | 3.0mm |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Connector Durability | 500 times |
| Tensile Strength | 90/180N (Long/Short Term) |
| Insertion Loss | ≤0.35dB (0.15dB Typ.) |
| Return Loss | ≥27dB |
| Attenuation at 850nm | ≤2.3dB/km |
| Attenuation at 1300nm | ≤0.6dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
Use this jumper anywhere a short multi-fiber connection is needed: panel to equipment, cassette to cassette, or switch to switch within a row. The 8-fiber version matches 400G and 800G parallel interfaces that run on 4 or 8 lanes, such as QSFP112, OSFP and twin-port OSFP connections. Because it arrives polished and tested, the installer only needs to route and connect it.
Choosing the right polarity is the key to a working MPO link. As a factory we build Type A, Type B and Type C versions of this cable, with male or female connectors on either end. If you are migrating an existing install, send us the current panel layout and we will confirm the correct combination before production.
Please reference 8FMTPOM4 in your enquiry. Our sales team can also advise on polarity, gender and jacket choices if your project documentation is not final yet.
Our test routine covers insertion loss, return loss and ferrule end face inspection on every assembly. Because testing is done in-house, custom variants receive exactly the same verification as standard models.
Every cable is protected with dust caps and individual packaging before being boxed for shipment. Batch test reports and your own part number labels can be included in each bag.
We have manufactured fiber optic assemblies since 1995. MPO and MTP cabling is one of our core lines: fiber counts from 8 to 144, single mode and multimode, UPC and APC polish, trunk, jumper, harness and breakout formats. Send your drawing and we turn it into a ready to install assembly.