MTP-8 to MTP-8 UPC Jumper, 8 Fibers, OM3, Type B

MTP-8 to MTP-8 UPC Jumper, 8 Fibers, OM3, Type B

This 8 Fibers MTP® Elite Female jumper is factory terminated and fully tested in our own facility, built on OM3 50/125μm fiber with a Plenum (OFNP) jacket. It is designed for high density patching inside data center cabinets, where pre-terminated cabling saves hours of field splicing and keeps polarity under control from day one.

Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.

Product Highlights

  • MTP® Elite Female (Non-Pinned) to MTP® Elite Female (Non-Pinned), 8 Fibers
  • OM3 50/125μm, bend insensitive fiber
  • Insertion loss ≤0.35dB (0.15dB Typ.), return loss ≥27dB
  • Type B polarity
  • 3.0mm Plenum (OFNP) round cable
  • Minimum bend radius 7.5mm
  • Ten standard lengths from 1m (3ft) to 40m (131ft), custom lengths built to order

Specifications

Part Number8FMTPOM3
ManufacturerHT
Connector AUS Conec MTP® Elite Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Fiber ModeOM3 50/125μm
Wavelength850/1300nm
Polish TypeUPC to UPC
PolarityType B
Cable JacketPlenum (OFNP)
Fiber Count8 Fibers
Glass FiberBend Insensitive Fiber
Cable Outside Diameter (OD)3.0mm
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Connector Durability500 times
Tensile Strength90/180N (Long/Short Term)
Insertion Loss≤0.35dB (0.15dB Typ.)
Return Loss≥27dB
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140℉)
Storage Temperature-20 to 70°C (-4 to 158℉)

Applications

This jumper is intended for high density data center patching. The 8-fiber version matches 400G and 800G parallel interfaces that run on 4 or 8 lanes, such as QSFP112, OSFP and twin-port OSFP connections. It works equally well in new structured cabling builds and in day-to-day moves, adds and changes where fast, error-free reconnection matters.

Polarity and Gender Options

Choosing the right polarity is the key to a working MPO link. As a factory we build Type A, Type B and Type C versions of this cable, with male or female connectors on either end. If you are migrating an existing install, send us the current panel layout and we will confirm the correct combination before production.

Ordering Information

Please reference 8FMTPOM3 in your enquiry. The 1m (3ft) version is the standard model; Our sales team can also advise on polarity, gender and jacket choices if your project documentation is not final yet.

Built to Your Spec

As a factory we can modify almost every detail of this product: length, jacket material and color, polarity, gender, breakout geometry, labeling and packaging. Non-standard variants are routine work for us, not a special project.

Quality and Testing

Our test routine covers insertion loss, return loss and ferrule end face inspection on every assembly. Because testing is done in-house, custom variants receive exactly the same verification as standard models.

Logistics

Most orders leave our facility within a few working days. Courier, air freight and sea freight are all available, and we are happy to hand goods to your nominated forwarder in China.