MTP-16 to MTP-16 APC Jumper, 16 Fibers, OM4, Crossover

MTP-16 to MTP-16 APC Jumper, 16 Fibers, OM4, Crossover

This 16 Fibers MTP®-16 Female with Offset Key jumper is factory terminated and fully tested in our own facility, built on OM4 50/125μm fiber with a Plenum (OFNP) jacket. It is designed for high density patching inside data center cabinets, where pre-terminated cabling saves hours of field splicing and keeps polarity under control from day one.

Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.

Product Highlights

  • MTP®-16 Female (Non-Pinned) with Offset Key to MTP®-16 Female (Non-Pinned) with Offset Key, 16 Fibers
  • OM4 50/125μm, bend insensitive fiber
  • Insertion loss ≤0.35dB (0.15dB Typ.), return loss ≥45dB
  • Crossover polarity
  • 3.0mm Plenum (OFNP) round cable
  • Minimum bend radius 7.5mm
  • Ten standard lengths from 1m (3ft) to 40m (131ft), custom lengths built to order

Specifications

Part Number16FMTPOM4
ManufacturerHT
Connector AUS Conec MTP®-16 Female (Non-Pinned) with Offset Key
Connector BUS Conec MTP®-16 Female (Non-Pinned) with Offset Key
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Polish TypeAPC to APC
PolarityCrossover
Cable JacketPlenum (OFNP)
Fiber Count16 Fibers
Glass FiberBend Insensitive Fiber
Cable Outside Diameter (OD)3.0mm
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Connector Durability500 times
Tensile Strength80/240N (Long/Short Term)
Insertion Loss≤0.35dB (0.15dB Typ.)
Return Loss≥45dB
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140℉)
Storage Temperature-10 to 70°C (14 to 158℉)

Applications

Use this jumper anywhere a short multi-fiber connection is needed: panel to equipment, cassette to cassette, or switch to switch within a row. The 16-fiber interface matches 400G SR8 optics, where all 16 fibers carry active transmit and receive lanes. Because it arrives polished and tested, the installer only needs to route and connect it.

Polarity and Gender Options

This model is supplied in the polarity shown in the specification table. Type A maps fiber 1 to fiber 1 straight through, Type B reverses the array, and Type C swaps adjacent pairs. Female (pinless) connectors mate with panels and cassettes; male (pinned) versions are available for direct transceiver connection. Tell us your cabling scheme and we will build the matching variant.

Ordering Information

Ordering is simple: send us 16FMTPOM4 and your required lengths and quantities, and we return a factory quote the same working day. The 1m (3ft) version is the standard model; Small trial orders are welcome before you commit to a full project rollout.

Quality and Testing

Every MPO/MTP assembly leaving our factory is 100% tested for insertion loss and return loss, with end face geometry checks on the multi-fiber ferrules. Controlled polishing keeps the loss budget stable across the whole batch, which matters when several mated pairs sit in one link.

Built to Your Spec

We have manufactured fiber optic assemblies since 1995. MPO and MTP cabling is one of our core lines: fiber counts from 8 to 144, single mode and multimode, UPC and APC polish, trunk, jumper, harness and breakout formats. Send your drawing and we turn it into a ready to install assembly.