Brocade 100G-Q28-Q28-C-0501 Compatible 100G QSFP28 4 x 25G NRZ Passive Copper Twinax Cable, 5m (16ft)

Brocade 100G-Q28-Q28-C-0501 Compatible 100G QSFP28 4 x 25G NRZ Passive Copper Twinax Cable, 5m (16ft)

The 100G-Q28-Q28-C-0501 compatible assembly is a 100G DAC cable for Brocade hosts, built in 5m (16ft) with QSFP28 to QSFP28. It serves as one complete direct-attached link, while the compatibility and diagnostic checks below address the host-specific identification needed in a mixed-equipment environment.

OEM Part Number: 100G-Q28-Q28-C-0501HT Part Number: 100G-Q28-Q28-C-0501

Product Highlights

  • Compatible alternative to Brocade 100G-Q28-Q28-C-0501
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to QSFP28
  • Fixed length and part number: 5m (16ft), 100G-Q28-Q28-C-0501
  • Cable construction: Passive Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 45mm

Specifications

HT Part Number100G-Q28-Q28-C-0501
Brocade Compatible100G-Q28-Q28-C-0501
ManufacturerHT
Form FactorQSFP28 to QSFP28
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length5m (16.4ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius45mm
Wire AWG26AWG
Max. Power Consumption≤0.5W
Modulation Format4x 25G-NRZ to 4x 25G-NRZ
Power Supply3.3V
MTBF≈50 Million Hours
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet
ProtocolsQSFP28 MSA, SFF-8662, IEEE 802.3

Signal and Lane Configuration

The listed modulation format is 4x 25G-NRZ to 4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 45mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet. Listed interface and protocol references include QSFP28 MSA, SFF-8662, IEEE 802.3. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 5m (16ft) length gives 100G-Q28-Q28-C-0501 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.

Position Within the Length Range

100G-Q28-Q28-C-0501 is the longest of 7 verified length options in this family. Compared with 100G-Q28-Q28-C-0301 at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Mixed-Vendor Network Operation

A mixed-vendor link should be documented at both ends, not treated as one generic connection. Confirm which OEM identity each host expects and whether the two ends use the same compatibility requirement. The related brand links below help locate equivalent-length assemblies, while the physical form factor and lane arrangement must still agree across the complete path. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 45mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).

Brocade Compatibility and Factory Testing

Testing addresses the brand-specific identification as well as the operating link and available diagnostics. The same physical cable family can require a different host identity for another equipment vendor, so the intended platform should be supplied when a deployment combines multiple brands or unusual hardware revisions. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For mixed-vendor projects, identify the equipment at both ends along with the OEM reference, length and quantity. Order each compatibility version under its own part number. If spare assemblies are required, list them separately so labels and test records remain unambiguous. Keep 100G-Q28-Q28-C-0501 associated with 5m (16ft) throughout the order and receiving record.

Quality Assurance and Packaging

Both ends are inspected and the complete assembly is powered up for a functional check before packing. Connectors are protected individually and the cable is secured without tight bends. Optional labels can distinguish host brand, OEM reference and length for easier spares management. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original Brocade cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 100G-Q28-Q28-C-0501.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Malaysia Fiber Optic Supplier

Malaysia Fiber Optics
Factory Address: Block 5, Wangtang Industrial Park,Nanshan Area, Shenzhen,China
Malaysia Office: 68000 Ampang,
Selangor, MY
https://www.fiberoptic.com.my